Technical Informations / Service Life
Temperature (°C) | Service Life (Year) | Operation Pressure (Bar) |
---|---|---|
20 | 1 | 30.0 |
5 | 28.1 | |
10 | 27.3 | |
25 | 26.5 | |
50 | 25.7 | |
30 | 1 | 25.5 |
5 | 23.9 | |
10 | 23.2 | |
25 | 22.3 | |
50 | 21.8 | |
40 | 1 | 21.5 |
5 | 20 2 | |
10 | 19.6 | |
25 | 18.8 | |
50 | 18.3 | |
50 | 1 | 18.3 |
5 | 17.0 | |
10 | 16.5 | |
25 | 15.9 | |
50 | 15.4 | |
60 | 1 | 15.4 |
5 | 14.3 | |
10 | 13.8 | |
25 | 13.3 | |
50 | 12.7 | |
65 | 1 | 14.6 |
5 | 13.6 | |
10 | 13.1 | |
25 | 12.6 | |
50 | 11.1 | |
70 | 1 | 13.0 |
5 | 11.9 | |
10 | 11.7 | |
25 | 10.1 | |
30 | 8.8 | |
50 | 8.5 |
Referans Standart:DIN 2000
Service Period | Temperature (°C) | Service Life (Year) | Operation Pressure (Bar) |
---|---|---|---|
30 days/year | 75 | 5 | 17.27 |
10 | 13 79 | ||
25 | 11.74 | ||
45 | 10.18 | ||
80 | 5 | 13.50 | |
10 | 13.80 | ||
25 | 11.14 | ||
42.5 | 9.79 | ||
85 | 5 | 12.42 | |
10 | 11.87 | ||
25 | 10.14 | ||
37.5 | 9.18 | ||
90 | 5 | 11.39 | |
10 | 10.94 | ||
25 | 8.86 | ||
35 | 8.16 | ||
60 days/year | 75 | 5 | 14.11 |
10 | 13.57 | ||
25 | 11.58 | ||
45 | 10 05 | ||
80 | 5 | 13.12 | |
10 | 12.54 | ||
25 | 10.56 | ||
40 | 9.41 | ||
85 | 5 | 12.03 | |
10 | 11.52 | ||
25 | 9.22 | ||
35 | 8.48 | ||
90 | 5 | 11.04 | |
10 | 9.76 | ||
25 | 7.81 | ||
30 | 7.46 | ||
90 days/year | 75 | 5 | 14.02 |
10 | 13.38 | ||
25 | 11.33 | ||
45 | 9.82 | ||
80 | 5 | 12 90 | |
10 | 12.35 | ||
25 | 10.05 | ||
37.5 | 9.08 | ||
85 | 5 | 11.81 | |
10 | 10 72 | ||
25 | 8.58 | ||
32.5 | 8.03 | ||
90 | 5 | 10 59 | |
10 | 8.96 | ||
25 | 7.17 |